Two Rails, One Truth

Migrating ADT notifications to FHIR without ripping out the rails the industry runs on

By Mario G. Hyland, Founder & SVP, AEGIS.net, Inc.  ·  October 2026

Admit, discharge, and transfer (ADT) events do a lot of unglamorous work in U.S. care coordination. When a patient arrives in an emergency department, an HL7 v2 ADT message usually reaches a care manager, a health plan, or a regional exchange within minutes. These feeds have carried event notifications for decades, and they work.

That reliability is what makes them so hard to replace. FHIR is where interoperability is heading: topic-based subscriptions, standardized attribution, more computable payloads, and APIs that payers and providers can both build on. But no health system, payer, or HIE is going to shut off thousands of production HL7 v2 and IHE interfaces on a Friday and turn on FHIR the following Monday. Nobody can afford a “rip and replace” cutover. The industry has largely settled whether to move to FHIR. The open question is how to get there while the existing rails keep running.

Why start with ADT

ADT is infrastructure. Nearly every organization in the care continuum produces or consumes it, it is event-driven by nature (the model FHIR Subscriptions was built for), and it crosses the payer-provider boundary every day. A migration path proven on ADT gives the industry a pattern it can reuse for most other exchanges.

Providers, payers, health IT developers, and federal stakeholders keep asking for the same improvements:

  • Richer content. Notifications that carry more clinical and administrative context than a v2 segment can comfortably hold.
  • Consistency. Fewer one-off, partner-specific versions of what is supposed to be the same feed.
  • Broader access. Notifications for payers, ACOs, and care-coordination organizations that sit outside the traditional feed.
  • Better attribution. Roster and attribution exchange based on standards such as the Da Vinci Member Attribution (ATR) IG, instead of spreadsheets.

The standards behind these needs are maturing quickly: FHIR Subscriptions and its R4 Backport, the Da Vinci Unsolicited Notifications IG, Da Vinci ATR, and federal efforts such as ONC’s LEAP project on FHIR Subscriptions. The specifications exist. What’s missing is a proven way to adopt them alongside the systems already in production.

Conformant messages do not guarantee interoperability

A notification is a lifecycle rather than a single message. A clinical event occurs; a message is generated, transformed, and routed; attribution identifies the right recipient; the notification is delivered; and someone acts on it. A failure at any of those handoffs breaks the exchange, even when every message along the way is valid.

We run into this often. A well-formed message goes to the wrong organization because the attribution data was stale. The right recipient has no discoverable endpoint. A routing decision that is technically valid conflicts with how the receiving organization actually works. Migration makes all of this harder, because each clinical event now exists in two forms, HL7 v2 and FHIR, and both have to mean the same thing.

Figure 1. Discover, resolve, transport: one network, many organizations, both rails. Organization C still prefers an HL7 v2 feed, and any migration has to accommodate partners like it.

Figure 1 shows a realistic environment. A health system, a payer, a regional exchange, and a public health agency each send and receive over both FHIR and HL7 v2. A shared Network Directory handles lookup only (discovery and endpoint resolution), and the organizations exchange data directly over the secure internet backbone, in either direction. Some partners are ready for FHIR now; others will run v2 for years. A workable migration plan has to serve both groups at once.

The AEGIS Dual-Rail Architecture

AEGIS designs around one principle: the same data, across different interfaces, now and in the future. Whether a partner receives an A03 discharge as an HL7 v2 message or as the equivalent FHIR notification, both must carry the same complete clinical meaning. The Dual-Rail Architecture applies that principle through four elements:

1. The legacy rail keeps running

Existing HL7 v2 ADT exchange (A01, A02, A03, A04, A08, A28/A31 and related events), along with IHE profiles such as ITI-31 Patient Encounter Management and PIX/PDQ for identity, continues without interruption. Coexistence comes first. Destabilizing a mechanism the industry depends on is the quickest way to lose stakeholders’ trust.

2. Per-event FHIR eligibility

ADT rarely travels straight from the EHR to the recipient. It usually passes through an integration or interface-engine layer, and that is where Dual-Rail operates. For each event, the layer determines whether the notification could also go out over a FHIR path, such as a Subscriptions topic or the Da Vinci Unsolicited Notifications IG, without affecting any existing v2 consumer.

3. Directory and attribution as routing infrastructure

Correct routing depends on knowing who is responsible for the patient and where they want to receive the event. Dual-Rail treats two services as core infrastructure: an endpoint directory that records each recipient’s supported and preferred channels, and member attribution informed by Da Vinci ATR.

4. Cross-standard equivalence, proven by test

Paired synthetic examples of the same ADT events, rendered in both HL7 v2 and FHIR, show implementers exactly how each event is expressed on each rail and give them a reference to test against. The pairs also surface gaps, such as a v2 concept with no clean FHIR equivalent or an IG requirement with no place for a v2-origin data element. We report each gap back to the standards community.

Moving in stages. Dual-Rail advances each partner and each flow only when the evidence supports it: